  • Reason for 2015 IBC 505. 2. 1 Mezzanine Area rule?
    Hi, I was hoping somebody could enlighten me about the reason why the IBC (2015) 505 2 1 forces a designer to enlarge the building until the unenclosed areas of the room enclosing the mezzanine amount to three times the mezzanine area: 505 1 General Mezzanines shall comply with Section 505 2
  • Mezzanine - The Building Code Forum
    Consider a room with a mezzanine For simplicity's sake lets call it a square box, type VB, NS The square box has a mezzanine running the perimeter of the floor below, like a race track going around it (This is not a gym with a racetrack) A portion of the mezzanine is cut off by walls that
  • Is a Mezzanine considered a floor? | The Building Code Forum
    The mezzanine is a "floor" and the level of exit discharge is at the floor level below (even though the mezzanine is part of that story) ClassicT provided one interpretation that is possible and I've provided another interpretation that is possible--this is just an extremely gray area of the code
  • Mezzanine vs. 2nd floor - The Building Code Forum
    As proposed, the mezzanine story sits above the B-range and extends out and over the M-retail space, and would be used as offices in support of the operation and accessory storage Without going too far into the weeds, the mezzanine story will be constructed within the existing attic, incorporating the widely spaced trusses into the space plans
  • Do I need an elevator? - The Building Code Forum
    We have a client who is interested in exploring the possibility of adding a mezzanine or second floor level above an existing area in a large multi-story assembly building The area we would be working on is 3,088 square feet While there are existing elevators in the building, they wouldn't be
  • Multi Story area with Stacked Mezzanines | The Building Code Forum
    In my opinion, the area on the left is a single-story space with four mezzanines, with the one mezzanine on the right having direct egress to the second story Just FYI, the total area of all mezzanines in the room on the left cannot exceed 1 3 the floor area of the room in which they are located
  • Mezzanine Size Calculation | The Building Code Forum
    MEZZANINE An intermediate level or levels between the floor and ceiling of any story The first question, then, is whether your mezzanine is, in fact, a mezzanine? Is it actually an intermediate level between the floor and ceiling of a story? Then there's the issue of the allowable size Mezzanines are addressed in section R325 of the IRC
  • Mezzanine: 1 3 of room - The Building Code Forum
    The aggregate area of a mezzanine or mezzanines within a room shall be not greater than one-third of the floor area of that room or space in which they are located The enclosed portion of a room shall not be included in a determination of the floor area of the room in which the mezzanine is located [Ryan Schultz: NO to A=1 3 (B+C) YES to A=1 3B]
  • Balconies Mezzanines Means of Egress - The Building Code Forum
    The IBC requires 2 exits from a mezzanine when the occupant load exceeds 49 (or lower in some occupancies) The NFPA section you quoted starts at 50+, so the 50th person is the difference Also note the IBC CPET limitations IBC 1006 1 General The number of exits or exit access doorways required within the means of egress system shall comply with the provisions of Section 1006 2 for spaces
  • Mezzanine egress - The Building Code Forum
    I have a mezzanine in an M use group which based on occupant load and being enclosed requires two means of egress The building is sprinklered We are separating the exits by the one-third diagonal distance, but our question is related to the arrangement of the two exits once they converge on