  • Segment 3 Quiz 2 Flashcards | Quizlet
    small appliance receptacle outlets ___ included in the 3 volt ampere per square foot load calculation the National Electrical Code requires receptacles installed in a garage to be ___ a continuous load shall not exceed ___ of the rating of the branch circuit
  • Chapter 3: Determining the Required Number of Branch Circuits . . . - Quizlet
    Calculate the minimum number of 15-ampere lighting branch circuits required if the dwelling has an occupied area of 4000 square feet? (Hint: It's a two-step process )
  • Get Wired 101. Lesson 12 Quiz. Flashcards | Quizlet
    Small appliance receptacle outlets ____ required to be included in the 3 volt-ampere per square foot load calculation The National Electrical Code generally requires receptacles installed in a garage to be GFCI-protected The exception (s) to this rule include ____ A continuous load shall not exceed ____ of the rating of the branch circuit
  • Engineering Terms Definitions | Get Wired 102 Study Set . . . - Quizlet
    Small appliance receptacle outlets __ required to be included in the 3 volt-ampere per square foot load calculation are not The National Electrical Code generally requires receptacles installed in a garage to be GFCI- protected The exception to this rule include ___
  • Lab chapter 3 Flashcards - Quizlet
    An individual 15 amp branch circuit is run to the receptacle outlet behind the refrigerator instead of connecting it to one of the two 20-ampere small-appliance branch circuits that are required in kitchens For this separate circuit, an additional 1500 volt-amperes (shall)(does not have to) be added to the load calculations for dwellings
  • Ch 6 - Branch Circuit Flashcards - Quizlet
    According to the NEC, the unit load used to calculate the minimum number of general lighting circuits in a dwelling is _____ volt-amperes per square foot bathroom In a residential wiring, a ____________ does not have its power supplied by a small appliance circuit
  • TABLE E3602. 2 - ICC Digital Codes
    Services that are not required to be 100 amperes shall be sized in accordance with Chapter 37 [230 42 (A), (B), and (C)] This comprehensive code comprises all building, plumbing, mechanical, fuel gas and electrical requirements for one- and two-family dwellings and townhouses up to three stories
  • Small appliance outlets are _____ included in the 3 volt-ampere per . . .
    In electrical engineering and specifically for the purposes of electrical wiring for buildings, small appliance outlets are typically not included in the 3 volt amp per sq ft calculations This rule primarily applies to North America, as the electrical code set forth by the National Electrical Code (NEC) excludes small appliance circuits from
  • Branch-Circuit, Feeder and Service Calculations, Part VII
    At least one 20-ampere laundry circuit and at least two 20-ampere small-appliance branch circuits are required While the bathroom branch circuit supplying receptacle outlets must be rated 20 amperes, no additional load calculation is required (see Figure 4)
  • Calculating General Lighting Loads for Residential Dwellings
    Each floor level must be considered individually, then added together to determine the total floor area for the calculation The floor area to be included in the calculation is not required to include any open porches, garages, or any unused or unfinished spaces that are not adaptable for future use