  • NEC Requirements for Generators and Standby Power Systems
    Mike Holt Enterprises, Inc • www MikeHolt com • 888 NEC CODE (632 2633) 5 NEC Requirements for Generators and Standby Power Systems 445 18 Disconnecting Means Generators must have one or more disconnecting means that disconnects all power, except where: Figure 445–7 (1) The driving means for the generator can be readily shut down, and
  • Continuous Load: what is maximum current - Electrician Talk
    From the 2023 NEC Article 100 Definition: Continuous Load: A load where the maximum current is expected to continue for 3 hours or more 210 20(A) Continuous and Noncontinuous Loads "Where a branch circuit supplies continuous loads or any combination of continuous and noncontinuous loads
  • 110. 14 Interpretation - Electrician Talk
    110 14(C) Temperature Limitations The temperature rating associated with the ampacity of a conductor shall be selected and coordinated so as not to exceed the lowest temperature rating of any connected termination,conductor,or device Conductors with temperature ratings higher than specified
  • FOOD TRUCKS - Electrician Talk
    Unfortunately I would say the answer lies with your local AHJ Being that you have a commercial kitchen on wheels I would lean towards the NEC is a factor The last one I did used a 3r panel to keep grease out of the box and covers that allow plugins and kept the 3r rating I piped the whole thing using compression fittings Flew through the AHJ
  • INTRODUCTION TO UNIT 5—RACEWAY AND BOX CALCULATIONS - Electrician Talk
    of the NEC are the primary references for determining allowable con-ductor fill in raceways For the most common condition, where multi-ple conductors of the same size are installed together in a raceway, the maximum number of conductors permitted can be determined from the tables in Annex C For situations where conductors of different
  • EMT Fittings for Damp Locations. | Electrician Talk
    NEC 358 42 Couplings and Connectors Couplings and connectors used with EMT shall be made up tight Where buried in masonry or concrete, they shall be concretetight type Where installed in wet locations, they shall comply with 314 15 No mention of "damp"
  • Motor disconnect - Electrician Talk
    Thanks micro and splatz, I read it as being able to lock the disconnect at the starter and that will suit the NEC, but I’m rough at best with the code book The situation is I have a roots blower at a plant to connect up and I’m strongly leaning towards split starting the 40hp motor on two NEMA 2 1 2 Furnas starters with a 1~2 second delay
  • 110. 15 High-Leg Marking - Electrician Talk
    Reading the NEC for this is nit picking I have worked with 100's of POCO's, I bet IF you can get a wild leg service they make up the rules NOT at all caring for what the NEC says Argue with the entity providing you power is a fools errand You do what they say, use the colors they say and be happy