  • Nozzle temperature malfunction. [0300 8008] - Troubleshooting . . .
    Nozzle temperature gradually dropped from 270C to 256C over about 2-3 minutes and it coded out again That seems more like a degraded hotend thermistor or a bad connection that degrades with heat With ASA - particularly large ASA prints like the one I’m trying to do, the chamber temperature should be quite warm to prevent warping
  • Help with nozzle temperature malfunction : r BambuLab - Reddit
    I had this same issue on my new X1C After the back and forth with support, 2 weeks later I had a new TH board I replaced that, and still the issue persists I assume after a few more days they will agree to send me the other tool head board to replace, meaning I will have had to wait a month to get this boat anchor running again
  • HMS_0300-0200-0001-0006: The nozzle temperature is abnormal . . .
    HMS_0300-0200-0001-0007: The nozzle temperature is abnormal, the sensor may be open circuit "The nozzle temperature is abnormal, the sensor may be open circuit " 0300-0200-0001-0007 ¶ End Notes We hope the detailed guide provided has been helpful and informative
  • Nozzle Temperature Incorrect (Over Under Temp)
    I get the error: Nozzle Over Temp - [0300 0200 0001 0003 1436 13] When searching, lots of people have similar issues: I had both under and over temp errors over the last year The best answer I got from Bambu was to unplug and replug the connectors for the fan It kinda helped, and for a few months it worked fine Then it happened again, no amount of wiggling cables helped I replaced the fan
  • Selective Solder Troubleshooting Guide - DDM Novastar
    Sunken joints may be seen on the topside and base of the board The most common cause for sunken joints is the hole to lead ratio If the hole is large in comparison to the lead diameter, the solder literally drops in or out of the hole Sunken solder joints can be caused by incorrect preheat or poor fluxing when seen on the topside of the board
  • Soldering Defects and Solutions - Fine Power Tools
    Setting the soldering temperature too low, which might lead to applying more solder than needed Applying solder before the joint has been appropriately heated can lead to using excessive solder Uneven heat distribution due to, for example, a damaged tip can require using more solder than needed and tends to create these joints